Brand: AKE
Valve Size: Up to 3.0 inches
Capacity: 0-10 liters
Media: Air, Water, Gas, Fuel
Body Material: Bronze
Tank Material: Brass
Internal Parts: Brass and Stainless Steel
Seat Disc: Silicone
Pressure Spring: Stainless Steel
Max Rated Pressure: 0-5 Bar, 5-10 Bar, 10-15 Bar, 3 Bar
Set Pressures: 75, 87, 100, 125, 150 psi (0.5, 0.6, 0.7, 0.8, 1.0 MPa)
Pressure Tolerance: +5%, -10%
Temperature Relief: 210°F (99°C) standard
Temperature Range: 65°C to 99°C
Temperature Tolerance: ±5°C
Service: Hot Water
Standard Compliance: ANSI Z21.22
Minimum Order Quantity: 1 Piece
Pressurized solar water heaters
Gas heaters
Electric water heaters
Fuel-based water heaters
Heat pump water heaters
Hot water storage tanks
Boilers and sensitive function heaters
Positioning: Install on the top or side of the water heater, ensuring the temperature-sensing element is immersed within the top 6 inches of the tank.
Pipeline Setup: Attach an elimination pipeline under the relief valve, with the terminal station at least 6 inches above the floor drain for easy removal and water observation.
Orientation: Can be directly installed on the top or side of the water heater.
Annual Check: Lift the relief valve handle at least once a year to ensure the waterway remains unblocked.
Safety Precautions: Verify that the elimination pipeline directs hot water to a safe location to prevent bodily injury.
Valve Inspection: If no water flows when the handle is lifted, the valve may be faulty. Immediately turn off the water heater and inspect or replace the valve.